Technical Specifications
Brand Welling & Crossley
Product Type Standby Diesel Generator
Fuel Diesel
Generator Type 3 Phase Generators
Generator Rating (kVA) 1 to 20kVA
Engine Brand Kubota
Pack Weight (KG):
0.00
Description

The Welling & Crossley ED9KYE/3-400 9kVA Three Phase Standby Diesel Generator is built for dependable backup power where three phase supply is required during a mains outage. Powered by a Kubota diesel engine and paired with a Crossley SLG series single bearing, 4-pole brushless alternator, this generator is designed to deliver reliable standby performance across rural, commercial, workshop, light industrial, and essential equipment applications.

This model is supplied with a large 400 litre diesel fuel tank, making it a practical option for sites where extended standby runtime and reduced refuelling frequency are important. The generator also includes a remote start/stop control system, auto-start control module, and weather protective acoustic canopy, giving customers a fully integrated Welling & Crossley power generation package designed for reliability, performance, and versatility.

The acoustic canopy helps protect the generator from the elements while reducing operating noise to approximately 70 dB(A) at 1 metre, or 63 dB(A) at 7 metres. The complete generating set is mounted on a heavy duty fabricated steel base frame, with anti-vibration pads fitted between the engine, alternator, and frame to help isolate vibration and support smoother operation.

For safer and more practical diesel storage, the ED9KYE/3-400 includes a fully bunded fuel tank compliant with AS 1940-2004, providing secondary containment to help retain and recover spillage if required. A trickle charge battery charger is also fitted to help ensure the generator is ready to start when needed.

The standard auto-start control module supports local or remote starting and provides key protection and monitoring functions, including alternator frequency and speed sensing, generator/load power monitoring, accumulated power monitoring, generator overload protection, engine speed protection, run-time scheduling, battery voltage monitoring, and static battery charging. It can also be configured to operate with an Automatic Transfer Switch for automatic standby power applications.

With its Kubota diesel engine, 415V three phase output, 400L bunded tank, acoustic canopy, brushless alternator, and remote start capability, the ED9KYE/3-400 is a strong choice for customers needing reliable three phase diesel standby power with extended on-site fuel capacity.


Starting is remote or local to the machine with a push Start/Stop button and includes
  • Alternator frequency & speed sensing
  • Fully configurable via the interface or PC using USB
  • Generator/load power monitoring
  • Accumulated power monitoring
  • Generator overload protection
  • Fuel and start outputs
  • Engine speed protection
  • Engine run-time scheduler
  • Battery voltage monitoring
  • Static battery charger
Features
Weather-protective Acoustic Canopy

A weather-protective acoustic enclosure is included to protect and prolong the life of your generator. Finished using a powder coat paint finish, this acoustic canopy will reduce the noise level of the generating set to approximately 70 dB(A) at 1 metre from the machine (63 dB(A) @ 7 m).


Heavy-duty fabricated steel base frame

The complete generating set is mounted as a whole onto a heavy-duty fabricated steel base frame. Anti-vibration pads are fixed between the engine and alternator feet and the base frame, ensuring complete vibration isolation of the rotating assembly.


Bunded Fuel Tank (AS 1940-2004 compliant)

The fuel tank is fully bunded and complies fully with relevant sections in AS 1940-2004. It has a secondary containment compound with a capacity as big or bigger than that of the tank, and is made of surface-coated steel. This compound is designed to sufficiently retain spillage and enable recovery of any spillage. For more information regarding AS 1940-2004 compliance, refer to the standard or contact us.


Battery Charger

This trickle charge battery charger ensures that your generator can start up when needed. It has both 12v and 24v charging capabilities.


Control Panel with Emergency Stop button

This control panel monitors the controls of a single unit to achieve automatic start/stop, data measuring/monitoring, alarm protection and three remote systems (remote control, remote measuring and remote communication). The controller adopts a large liquid crystal display (LCD) and has a 32-bit microprocessor with precision parameters for measuring, fixed value adjustment, time setting and threshold adjustment.


Prime or Standby Power

Standby: kVA @ 0.8 pf. These ratings are applicable for supplying continuous electrical power (at variable loads) in the event of a utility power failure. No overload is permitted on these ratings. Minimum output from alternators is peak continuous rated (as defined in 1SO 8528-3 @ 27°C. Annual hour limitation: 500 hours).

Prime (continuous): kVA @ 0.8 pf. (Divide standby rating by 1.1). Available for continuous electrical output. There is no hour limitation. 10% overload is available for 1 hour in 12. The generating set and this specification are designed for environmental conditions of up to 27°C, up to 152.4 m above sea level and up to 60% relative humidity. Ratings at 0.8 pf. For ratings outside this range, please contact us.


Alternator Specifications
Alternator Model Crossley
Electric Power Three Phase
Active Rating 9 kVA at 0.8 pf (Standby)
Power 7.2 kW
Voltage 415V
Frequency 50Hz

Engine Specifications
Engine Model Kubota D114
Engine Speed 1500 rpm
Cylinder No. 3
Cubic Capacity 1.498 L
Bore/Stroke 78 x 78.4 mm
Compression Ratio 23.0:1
Aspiration Natural
Starter Voltage 12V
Flywheel (Max Continuous Power) 8.4 kW
Combustion Air Flow 1 m³/min
Cooling Air Flow 35 m³/min
Cooling System Radiator Cooled
Heat Rejection to Cooling System 8kW
Exhaust Gas Flow 2.2 m³/min
Exhaust Gas Temperature 550°C
Fuel Type Diesel
Fuel Tank Capacity 400 L
Approx. Fuel Consumption (Continuous) 2.75 L/hr
Approx. Fuel Consumption (Standby) 3.0 L/hr

Generator Specifications
Dimensions (L x W x H) 1800 x 900 x 1500 mm
Weight 1165 kg