10.5 kVA, Single Phase, Standby Diesel Generator with Kubota Engine in Canopy, 400L Tank

Order Code: 415904

Print
Product Code
ED10.5KYE-400
RRP: $20212.50 incl. GST

Request a Quote Now

Click the link below to connect with our team.
We’ll help you define the technical requirements for your Standby Generator.

Request Quote

Precision-Built. Performance-Tested. Fast Turnaround.

Welling & Crossley Generators are assembled and tested in our advanced Melbourne facility, ensuring each unit meets the performance and reliability standards demanded by Australian conditions.

With a typical 5–10 day turnaround, our local assembly allows for rapid delivery without compromising on quality. Submit a quote request today, and our technical team will assess your requirements to configure the most suitable product for your application.

Technical Specifications
Brand Welling & Crossley
Product Type Standby Generator
Fuel Diesel
Generator Type Single Phase
Generator Rating (kVA) 1 to 20kVA
Pack Weight (KG):
0.00
Description

The Welling & Crossley ED10.5KYE-400 10.5kVA Single Phase Standby Diesel Generator is designed for customers who need dependable single phase backup power with extended on-site fuel capacity. Powered by a proven Kubota V1505-E2BG diesel engine and matched with a Crossley SLG series single bearing, 4-pole brushless alternator, this generator is built to provide reliable standby performance for residential, rural, commercial, workshop, and light industrial applications.

This model includes a large 400 litre bunded diesel fuel tank, making it a practical choice for sites where longer standby runtime and reduced refuelling frequency are important. Supplied as a complete Welling & Crossley power generation system, the ED10.5KYE-400 also includes a remote start/stop control system, auto-start control module, weather protective acoustic canopy, and heavy duty base frame.

The weather protective acoustic canopy helps protect the generator from the elements while reducing operating noise to approximately 73 dB(A) at 1 metre, or 65 dB(A) at 7 metres. The complete generating set is mounted on a heavy duty fabricated steel base frame, with anti-vibration pads fitted between the engine, alternator, and frame to help isolate vibration and support smoother operation.

For safer diesel storage on site, the ED10.5KYE-400 includes a fully bunded fuel tank compliant with AS 1940-2004, providing secondary containment designed to help retain and recover spillage if required. A trickle charge battery charger is also fitted to help ensure the generator is ready to start when needed.

The standard auto-start control module supports local or remote starting and provides key monitoring and protection functions, including alternator frequency and speed sensing, generator/load power monitoring, accumulated power monitoring, generator overload protection, fuel and start outputs, engine speed protection, run-time scheduling, battery voltage monitoring, and static battery charging. It can also be configured to operate with an Automatic Transfer Switch for automatic standby power applications.

With its Kubota diesel engine, 10.5kVA standby rating, 400L bunded tank, Crossley brushless alternator, acoustic canopy, and remote start capability, the ED10.5KYE-400 is well suited to customers needing reliable single phase diesel standby power with extended fuel capacity.


Starting is remote or local to the machine with a push Start/Stop button and includes
  • Alternator frequency & speed sensing
  • Fully configurable via the interface or PC using USB
  • Generator/load power monitoring
  • Accumulated power monitoring
  • Generator overload protection
  • Fuel and start outputs
  • Engine speed protection
  • Engine run-time scheduler
  • Battery voltage monitoring
  • Static battery charger
Features
Weather-protective Acoustic Canopy

A weather-protective acoustic enclosure is included to protect and prolong the life of your generator. Finished using a powder coat paint finish, this acoustic canopy will reduce the noise level of the generating set to approximately 70 dB(A) at 1 metre from the machine (63 dB(A) @ 7 m).


Heavy-duty fabricated steel base frame

The complete generating set is mounted as a whole onto a heavy-duty fabricated steel base frame. Anti-vibration pads are fixed between the engine and alternator feet and the base frame, ensuring complete vibration isolation of the rotating assembly.


Bunded Fuel Tank (AS 1940-2004 compliant)

The fuel tank is fully bunded and complies fully with relevant sections in AS 1940-2004. It has a secondary containment compound with a capacity as big or bigger than that of the tank, and is made of surface-coated steel. This compound is designed to sufficiently retain spillage and enable recovery of any spillage. For more information regarding AS 1940-2004 compliance, refer to the standard or contact us.


Battery Charger

This trickle charge battery charger ensures that your generator can start up when needed. It has both 12v and 24v charging capabilities.


Control Panel with Emergency Stop button

This control panel monitors the controls of a single unit to achieve automatic start/stop, data measuring/monitoring, alarm protection and three remote systems (remote control, remote measuring and remote communication). The controller adopts a large liquid crystal display (LCD) and has a 32-bit microprocessor with precision parameters for measuring, fixed value adjustment, time setting and threshold adjustment.


Prime or Standby Power

Standby: kVA @ 0.8 pf. These ratings are applicable for supplying continuous electrical power (at variable loads) in the event of a utility power failure. No overload is permitted on these ratings. Minimum output from alternators is peak continuous rated (as defined in 1SO 8528-3 @ 27°C. Annual hour limitation: 500 hours).

Prime (continuous): kVA @ 0.8 pf. (Divide standby rating by 1.1). Available for continuous electrical output. There is no hour limitation. 10% overload is available for 1 hour in 12. The generating set and this specification are designed for environmental conditions of up to 27°C, up to 152.4 m above sea level and up to 60% relative humidity. Ratings at 0.8 pf. For ratings outside this range, please contact us.


Alternator Specifications
Alternator Model Crossley
Electric Power Single Phase
Active Rating 10.5 kVA at 0.8 pf (Standby)
Power 8.4 kW
Voltage 240V
Frequency 50Hz

Engine Specifications
Engine Model Kubota V1505-E2BG
Engine Speed 1500 rpm
Cylinder No. 4
Cubic Capacity 1.498 L
Bore/Stroke 78 x 78.4 mm
Compression Ratio 16.18 : 1
Aspiration Natural
Starter Voltage 12V
Flywheel (Max Continuous Power) 12.2 kW
Combustion Air Flow 1 m³/min
Cooling Air Flow 40 m³/min
Cooling System Radiator Cooled
Heat Rejection to Cooling System 12.0kW
Exhaust Gas Flow 2.5 m³/min
Exhaust Gas Temperature 550°C
Fuel Type Diesel
Fuel Tank Capacity 4000 L
Approx. Fuel Consumption (Continuous) 4.0 L/hr
Approx. Fuel Consumption (Standby) 4.4 L/hr

Generator Specifications
Dimensions (L x W x H) 2000 x 900 x 1500 mm
Weight 1240 kg
Product Range Brochure
Downloads
Product Information and Data Sheets
Download Product Information & Data Sheets v1.0