63kVA, Three Phase, Standby Diesel Generator with Cummins Engine with 400L Tank - Hire

Order Code: 421383

Print
Product Code
ED63CUYE/3-SH
RRP: $36382.50 incl. GST

Request a Quote Now

Click the link below to connect with our team.
We’ll help you define the technical requirements for your Standby Generator.

Request Quote

Precision-Built. Performance-Tested. Fast Turnaround.

Welling & Crossley Generators are assembled and tested in our advanced Melbourne facility, ensuring each unit meets the performance and reliability standards demanded by Australian conditions.

With a typical 5–10 day turnaround, our local assembly allows for rapid delivery without compromising on quality. Submit a quote request today, and our technical team will assess your requirements to configure the most suitable product for your application.

Technical Specifications
Brand Welling & Crossley
Product Type Standby Diesel Generator
Fuel Diesel
Generator Type 3 Phase Generators
Generator Rating (kVA) 51 to 100kVA
Engine Brand Cummins
Pack Weight (KG):
0.00
Description

The Welling & Crossley ED63CuYE/3-SH 63kVA Three Phase Standby Diesel Generator – Hire is a heavy-duty, hire-ready diesel generator designed to deliver dependable 415V three phase standby power across temporary site power, commercial, rural, industrial, and essential equipment applications. Powered by a Cummins 4BTA3.9G2 turbocharged diesel engine and paired with a Crossley SLG Series single bearing, 4-pole brushless alternator, this unit is built for practical field use where reliability, performance, and ease of operation are critical.

Supplied with a 400 litre diesel fuel tank, remote start/stop control system, auto-start control module, and weather protective acoustic canopy, the ED63CuYE/3-SH is well suited to hire fleets, temporary worksites, rural operations, workshops, commercial backup, infrastructure support, and larger site power requirements. The hire configuration includes practical site-use features such as 3 x 15A single phase outlets, 1 x 32A 5-pin three phase outlet, IP66 RCD protected outlets, starter isolator, battery isolator, external hard-wired connection point, external fuel fill point, external oil, fuel, bund and coolant drain points, and lifting points.

The acoustic canopy helps protect the generator from the elements while reducing operating noise to approximately 70 dB(A) at 1 metre, or 63 dB(A) at 7 metres. The generating set is mounted on a heavy duty fabricated steel base frame, with anti-vibration pads fitted between the engine, alternator, and base frame to help isolate vibration and support smooth operation.

For safer diesel storage on site, the ED63CuYE/3-SH includes a fully bunded fuel tank compliant with AS 1940-2004, providing secondary containment designed to retain and recover spillage if required. A trickle charge battery charger is also fitted to help ensure the generator is ready to start when needed.

The standard auto-start control module supports remote or local starting and provides key monitoring and protection functions, including alternator frequency and speed sensing, generator/load power monitoring, accumulated power monitoring, generator overload protection, fuel and start outputs, engine speed protection, run-time scheduling, battery voltage monitoring, and static battery charging. It can also be configured to operate with an Automatic Transfer Switch for automatic standby power applications.

With its Cummins diesel engine, 63kVA standby rating, 415V three phase output, 400L bunded tank, acoustic canopy, RCD protected outlets, and hire-focused access features, the ED63CuYE/3-SH is a strong choice for customers needing reliable three phase diesel standby power in a robust, site-ready generator package.


Starting is remote or local to the machine with a push Start/Stop button and includes
  • Alternator frequency & speed sensing
  • Fully configurable via the interface or PC using USB
  • Generator/load power monitoring
  • Accumulated power monitoring
  • Generator overload protection
  • Fuel and start outputs
  • Engine speed protection
  • Engine run-time scheduler
  • Battery voltage monitoring
  • Static battery charger
Features
Weather-protective Acoustic Canopy

A weather-protective acoustic enclosure is included to protect and prolong the life of your generator. Finished using a powder coat paint finish, this acoustic canopy will reduce the noise level of the generating set to approximately 70 dB(A) at 1 metre from the machine (63 dB(A) @ 7 m).


Heavy-duty fabricated steel base frame

The complete generating set is mounted as a whole onto a heavy-duty fabricated steel base frame. Anti-vibration pads are fixed between the engine and alternator feet and the base frame, ensuring complete vibration isolation of the rotating assembly.


Bunded Fuel Tank (AS 1940-2004 compliant)

The fuel tank is fully bunded and complies fully with relevant sections in AS 1940-2004. It has a secondary containment compound with a capacity as big or bigger than that of the tank, and is made of surface-coated steel. This compound is designed to sufficiently retain spillage and enable recovery of any spillage. For more information regarding AS 1940-2004 compliance, refer to the standard or contact us.


Battery Charger

This trickle charge battery charger ensures that your generator can start up when needed. It has both 12v and 24v charging capabilities.


Control Panel with Emergency Stop button

This control panel monitors the controls of a single unit to achieve automatic start/stop, data measuring/monitoring, alarm protection and three remote systems (remote control, remote measuring and remote communication). The controller adopts a large liquid crystal display (LCD) and has a 32-bit microprocessor with precision parameters for measuring, fixed value adjustment, time setting and threshold adjustment.


Prime or Standby Power

Standby: kVA @ 0.8 pf. These ratings are applicable for supplying continuous electrical power (at variable loads) in the event of a utility power failure. No overload is permitted on these ratings. Minimum output from alternators is peak continuous rated (as defined in 1SO 8528-3 @ 27°C. Annual hour limitation: 500 hours).

Prime (continuous): kVA @ 0.8 pf. (Divide standby rating by 1.1). Available for continuous electrical output. There is no hour limitation. 10% overload is available for 1 hour in 12. The generating set and this specification are designed for environmental conditions of up to 27°C, up to 152.4 m above sea level and up to 60% relative humidity. Ratings at 0.8 pf. For ratings outside this range, please contact us.


Alternator Specifications
Alternator Model Crossley SLG Series
Electric Power Three Phase
Active Rating 63 kVA at 0.8 pf (Standby)
Power 52 kW
Voltage 415V
Frequency 50Hz

Engine Specifications
Engine Model Cummins 4BTA3.9G2
Engine Speed 1500 rpm
Cylinder No. 4TA
Cubic Capacity 3.9 L
Bore/Stroke 102 x 119 mm
Compression Ratio 17.3 : 1
Aspiration Turbocharged
Starter Voltage 24V
Flywheel (Max Continuous Power) 60 kW
Combustion Air Flow 4.2 m³/min
Cooling Air Flow 198 m³/min
Cooling System Radiator Cooled
Heat Rejection to Cooling System 56 kW
Exhaust Gas Flow 8 m³/min
Exhaust Gas Temperature 550°C
Fuel Type Diesel
Fuel Tank Capacity 400 L
Approx. Fuel Consumption (Continuous) 11.7 L/hr
Approx. Fuel Consumption (Standby) 13.0 L/hr

Generator Specifications
Dimensions (L x W x H) 3000 x 1100 x 1745 mm
Weight 1870 kg
Product Range Brochure
Downloads
Product Information and Data Sheets
Download Product Information & Data Sheets v1.0