18 kVA, Three Phase, Standby Diesel Generator with Kubota Engine in Canopy, 400L Tank & Load Bank

Order Code: 415979

Print
Product Code
ED18KYE/3-400-LB
RRP: $24255.00 incl. GST

Request a Quote Now

Click the link below to connect with our team.
We’ll help you define the technical requirements for your Standby Generator.

Request Quote

Precision-Built. Performance-Tested. Fast Turnaround.

Welling & Crossley Generators are assembled and tested in our advanced Melbourne facility, ensuring each unit meets the performance and reliability standards demanded by Australian conditions.

With a typical 5–10 day turnaround, our local assembly allows for rapid delivery without compromising on quality. Submit a quote request today, and our technical team will assess your requirements to configure the most suitable product for your application.

Technical Specifications
Brand Welling & Crossley
Product Type Standby Diesel Generator
Fuel Diesel
Generator Type 3 Phase Generators
Generator Rating (kVA) 1 to 20kVA
Engine Brand Kubota
Pack Weight (KG):
0.00
Description

The Welling & Crossley ED18KYE/3-400-LB 18kVA Three Phase Standby Diesel Generator is a complete backup power solution designed for applications that require reliable 415V three phase power, extended fuel capacity, and added protection against light-load running. This model is listed as a Welling & Crossley 18 kVA three phase standby diesel generator with Kubota engine, canopy, 400L tank and load bank, with product code ED18KYE/3-400-LB and order code 415979.

Powered by a proven Kubota D1803-M diesel engine and matched with a Crossley brushless alternator, this generator is well suited to rural, commercial, workshop, light industrial, and essential equipment backup applications where dependable standby performance matters.

The integrated 400 litre diesel fuel tank makes this model a practical choice for sites where longer standby runtime and reduced refuelling frequency are important. The addition of a load bank helps support healthier engine operation when site demand is low by applying artificial load, reducing the risk of light-load running issues and helping the generator operate more effectively over time.

Supplied in a weather protective acoustic canopy, the ED18KYE/3-400-LB is designed to protect the generator from the elements while helping manage operating noise on site. The complete generating set is mounted on a heavy duty base frame, with vibration isolation between the engine, alternator, and frame to support smoother operation.

The unit is designed as a fully integrated standby generator package, with remote start/stop capability and compatibility with automatic standby power applications. White International notes that Welling & Crossley generators are assembled and tested in its Melbourne facility, with local assembly supporting fast turnaround and configuration to application requirements.

With its Kubota diesel engine, 18kVA standby rating, 415V three phase output, 400L tank, acoustic canopy, integrated load bank, and remote start capability, the ED18KYE/3-400-LB is a strong choice for customers needing reliable three phase diesel standby power with extended fuel capacity and added protection for light-load operation.

With its Kubota diesel engine, 18kVA standby rating, 415V three phase output, 400L bunded tank, Crossley brushless alternator, acoustic canopy, and remote start capability, the ED18KYE/3-400 is a strong choice for customers needing reliable three phase diesel standby power with extended fuel capacity in a professionally built generator package.

With its Kubota diesel engine, 14.5kVA standby rating, 415V three phase output, 400L bunded tank, acoustic canopy, Crossley brushless alternator, and remote start capability, the ED14.5KYE/3-400 is a strong choice for customers needing reliable three phase diesel standby power with extended fuel capacity in a professionally built generator package.


Starting is remote or local to the machine with a push Start/Stop button and includes
  • Alternator frequency & speed sensing
  • Fully configurable via the interface or PC using USB
  • Generator/load power monitoring
  • Accumulated power monitoring
  • Generator overload protection
  • Fuel and start outputs
  • Engine speed protection
  • Engine run-time scheduler
  • Battery voltage monitoring
  • Static battery charger
Features
Weather-protective Acoustic Canopy

A weather-protective acoustic enclosure is included to protect and prolong the life of your generator. Finished using a powder coat paint finish, this acoustic canopy will reduce the noise level of the generating set to approximately 70 dB(A) at 1 metre from the machine (63 dB(A) @ 7 m).


Heavy-duty fabricated steel base frame

The complete generating set is mounted as a whole onto a heavy-duty fabricated steel base frame. Anti-vibration pads are fixed between the engine and alternator feet and the base frame, ensuring complete vibration isolation of the rotating assembly.


Bunded Fuel Tank (AS 1940-2004 compliant)

The fuel tank is fully bunded and complies fully with relevant sections in AS 1940-2004. It has a secondary containment compound with a capacity as big or bigger than that of the tank, and is made of surface-coated steel. This compound is designed to sufficiently retain spillage and enable recovery of any spillage. For more information regarding AS 1940-2004 compliance, refer to the standard or contact us.


Battery Charger

This trickle charge battery charger ensures that your generator can start up when needed. It has both 12v and 24v charging capabilities.


Control Panel with Emergency Stop button

This control panel monitors the controls of a single unit to achieve automatic start/stop, data measuring/monitoring, alarm protection and three remote systems (remote control, remote measuring and remote communication). The controller adopts a large liquid crystal display (LCD) and has a 32-bit microprocessor with precision parameters for measuring, fixed value adjustment, time setting and threshold adjustment.


Prime or Standby Power

Standby: kVA @ 0.8 pf. These ratings are applicable for supplying continuous electrical power (at variable loads) in the event of a utility power failure. No overload is permitted on these ratings. Minimum output from alternators is peak continuous rated (as defined in 1SO 8528-3 @ 27°C. Annual hour limitation: 500 hours).

Prime (continuous): kVA @ 0.8 pf. (Divide standby rating by 1.1). Available for continuous electrical output. There is no hour limitation. 10% overload is available for 1 hour in 12. The generating set and this specification are designed for environmental conditions of up to 27°C, up to 152.4 m above sea level and up to 60% relative humidity. Ratings at 0.8 pf. For ratings outside this range, please contact us.


Alternator Specifications
Alternator Model Crossley
Electric Power Three Phase
Active Rating 18 kVA at 0.8 pf (Standby)
Power 14.4 kW
Voltage 415V
Frequency 50Hz

Engine Specifications
Engine Model Kubota D1803-M
Engine Speed 1500 rpm
Cylinder No. 3
Cubic Capacity 1.826 L
Bore/Stroke 87 x 92.4 mm
Compression Ratio 16 : 1
Aspiration Natural
Starter Voltage 12V
Flywheel (Max Continuous Power) 19 kW
Combustion Air Flow 1.6 m³/min
Cooling Air Flow 48 m³/min
Cooling System Radiator Cooled
Heat Rejection to Cooling System 12.8kW
Exhaust Gas Flow 4.8 m³/min
Exhaust Gas Temperature 550°C
Fuel Type Diesel
Fuel Tank Capacity 400 L
Approx. Fuel Consumption (Continuous) 5.13 L/hr
Approx. Fuel Consumption (Standby) 5.7 L/hr

Generator Specifications
Dimensions (L x W x H) 2000 x 900 x 1580 mm
Weight 1240 kg
Product Range Brochure
Downloads
Product Information and Data Sheets
Download Product Information & Data Sheets v1.0